Sie müssen Optionen für das Produkt wählen.
- Regulärer Preis
- Price on request (RFQ)
Part Sourcing Brief
This product can be reviewed for industrial spare parts sourcing, replacement, maintenance, repair, and MRO procurement requirements.
Recommended RFQ details
- Required quantity
- Delivery country
- Photos, label, nameplate, or technical document if available
Quote, lead time, alternatives, and shipping options are confirmed after technical RFQ review.
Abholung nicht verfügbar
NEPS 1000 Pumped Purge Systems - Industrial Spare Part RFQ
Brand: AGM Container Controls
Part Number / SKU: neps-pumped
Product Family: Moisture Purging > Single Point Purge
This AGM Container Controls item is listed on AltraParts for industrial sourcing and RFQ-based procurement. Send your required quantity, delivery country, target lead time, and any technical requirements for quotation review.
Product Information
NEPS 1000 Pumped Purge Systems SKU: neps-pumped NEPS 1000 Pumped Purge Systems Categories Moisture Purging , Single Point Purge Description Nitrogen Enhanced Purging Systems Selection Guide Air Source Embedded Dry Air NEPS Type Standard Voltage 24 Volt 110 Volt 240 Volt 100-230 VAC/24 VDC Part Number NP24-AGM NP110-AGM NP240-AGM NPDV-AGM The NEPS 1000 Pumped purge systems were developed for field service applications where it is impractical or burdensome to provide a dry air source such as bottled nitrogen. The NEPS 1000 Pumped systems utilize an internal pump and a refillable cartridge containing 1 kilogram of molecular sieve desiccant to create dry air for the purging operation. Our Nitrogen Enhanced Purge System (NEPS) technology is a unique, easy-to-use, single-point purge system that pressurizes equipment or enclosures with dry gas to remove moisture from the airspace and from the hygroscopic materials contained in the equipment. This provides a more thorough purge and more efficient use of dry gas, as compared to a traditional dual-point or through purge when the dry gas will typically follow the path of least resistance from the entry to exit point of the equipment. The NEPS provides automatic operation with minimal user input. The embedded dew point sensor measures and displays the dew point of the air exiting the equipment during the depressurization cycle. This quantification of the purge operation ensures the effectiveness of the purge and prevents unnecessary dry gas expenditure. Additional features include adjustable pressure settings, equipment leak test and source gas dryness test. Most dual-point purging is done without any way to quantify the results. Quite often, the purge removes the moisture from the airspace, but is not performed in a manner to ensure the removal of the majority of the moisture, which is contained in the hygroscopic materials in the equipment. The NEPS eliminates this guesswork and provides an efficient and effective purge which will reduce the amount of dry gas expended, extend the life of the desiccant (if used), reduce maintenance cycles and provide greater protection to your equipment. The NEPS 1000 Pumped range of products are suitable for use with sealed electro-optical equipment, containers and enclosures. See Filler Valves for information on filler/purge valves for use with the NEPS. The NEPS 1000 Pumped models are mounted in a portable transit case. The control panel includes 1/4" NPT quick disconnects for inlet, outlet and exhaust ports and digital displays for dew point and pressure readings. Models available for use with 110 volt, 240 volt and 24 volt power source. A dual voltage model is also available for use with this range of power sources. Power cord, connection tubing and tubing flow restrictors included. Features Pumped Models Dual Voltage Model Fully Self-Contained for Portable Use User-Programmable Easy-to-Use Single Connection Purging Automatic Purging Operation Easy-to-Use Single Connection Purging Automatic Purging Operation Dew Point and Pressure Readout Dewpointstat Gas Control Dew Point and Pressure Readout Dewpointstat Gas Control Remote Dew Point Sensing Option Dew Point Display from +20°C to -80°C Remote Dew Point Sensing Option Dew Point Display from +20°C to -80°C Portable and Robust Maintainable Online Robust Maintainable Online User-Programmable NATO Approved NATO Approved Technical Specifications Pumped Models Selectable Pressure Ranges 10.3 Kpa (1.5 psi) Data Outp
Technical Details
Voltage | Choose an option 24 Volt 110 Volt 240 Volt 100-230 VAC/24 VDC Clear Nitrogen Enhanced Purging Systems Selection Guide Air Source | Embedded Dry Air NEPS Type | Standard Voltage | 24 Volt | 110 Volt | 240 Volt | 100-230 VAC/24 VDC Part Number | NP24-AGM | NP110-AGM | NP240-AGM | NPDV-AGM Pumped Models | Dual Voltage Model Fully Self-Contained for Portable Use | User-Programmable | Easy-to-Use Single Connection Purging | Automatic Purging Operation Easy-to-Use Single Connection Purging | Automatic Purging Operation | Dew Point and Pressure Readout | Dewpointstat Gas Control Dew Point and Pressure Readout | Dewpointstat Gas Control | Remote Dew Point Sensing Option | Dew Point Display from +20°C to -80°C Remote Dew Point Sensing Option | Dew Point Display from +20°C to -80°C | Portable and Robust | Maintainable Online Robust | Maintainable Online | User-Programmable | NATO Approved NATO Approved Pumped Models Selectable Pressure Ranges | 10.3 Kpa (1.5 psi) | Data Output Dew Point | 0-5 Volts 17.2 Kpa (2.5 psi) | Power | 100-230 volt 50 hz - 60 hz 34.4 Kpa (5.0 psi) | Power Consumption | 3 amps Display Range Pressure | 0 to 34.4 Kpa (0-5.0 psi) | Dimensions (mm) | 490W x 425D x 190H (closed) Display Range Dew Point | (Selectable) | Weight | 15 kg (33 lbs.) +20°C to -80°C dew point | Ingress Protection | IP54 (closed case) +68°F to -94°C dew point | Operating Temp | -10°C to +50°C (14°F to 122°F) Resolution | 0.1°C dew point | Storage Temp | -50°C to +65°C (-58°F to 149°F) Accuracy | ±2°C dew point | Flow Rate (typical) | 20 liters per minute (0.71 CFM) Data Output Pressure | 0-5 Volts | Optional Extras | See NEPS Accessories Nato Stock NSN | Order Code NP240 | 4440-99-912-6628 | NP240-AGM NP110 | 4440-99-404-2677 | NP110-AGM NP24 | 6625-99-821-5023 | NP24-AGM Dual Voltage Model Usable Gases | Air, Nitrogen, SF6, Helium, Argon | Power 1 | 100-230 volt 50 hz - 60 hz Selectable Pressure Ranges | 10.3 Kpa (1.5 psi) | Power Consumption | 3 amps 17.2 Kpa (2.5 psi) | Power 2 | 24 VDC Display Range Dew Point | (Selectable) | Weight | 10 kg (23 lbs.) Data Output Dew Point | 0-5 Volts | Order Code | NPDV-AGM Voltage | 24 Volt, 110 Volt, 240 Volt, 100-230 VAC/24 VDC Enclosure | Standard Additional Information
Technical Documents
Technical drawing, STEP file, datasheet or product document links were detected from the source page. Please verify the latest revision before ordering.
RFQ Notes
- Original brand and part number should be confirmed during quotation.
- Availability, lead time, and shipping options are confirmed after RFQ review.
- For replacement or equivalent sourcing, include photos, nameplate data, and existing part references.
Technical RFQ Notes
For a faster technical review, include the product reference, required quantity, delivery country, photos, nameplate details, drawings, manuals, or datasheets when available. AltraParts reviews industrial spare parts requests for maintenance, replacement, repair, and MRO procurement needs.
Availability, compatible alternatives, lead time, and shipping options are confirmed after RFQ review.
-
Schneller weltweiter Versand
Weltweiter Versand • Schneller Versand • Zuverlässige Spediteure
-
Sendungsverfolgung & sichere Verpackung
Sendungsverfolgung • Sichere Verpackung • Beschädigungssichere Handhabung
-
Zoll & Dokumentation inklusive
Zolldokumente inklusive • Exportformalitäten erledigt • Reibungslose Abfertigung
-
Angebotsanfrage (RFQ) für B2B-Bestellungen
Angebot per E-Mail anfordern • B2B-Preise verfügbar • Schnelle Antwort